Promotions INQUIRY: +91 9916040249

Hach LDO Model 2, DO Probe with Luminescent Dissolved Oxygen Technology, for Sea Water Applications

Hach LDO Model 2, DO Probe with Luminescent Dissolved Oxygen Technology, for Sea Water Applications
Product #: 9020000-SW
Unit Price Contact Hach

No Calibration Required

The Hach LDO probe uses luminescent dissolved oxygen technology. Traditional DO probes require DO sensor calibration, which increase maintenance requirements.

No Membranes to Replace

There is virtually no maintenance with Hach's breakthrough luminescent technology, as there are no membranes to replace, no electrolyte solution to replenish, and no anode or cathode to clean.

No Missed Cleaning Cycles

The Hach LDO probe is equipped with Prognosys, a predictive diagnostic system, that allows you to be proactive in your maintenance by alerting you to upcoming instrument issues. Know with confidence whether changes in your dissolved oxygen level measurements are due to changes in your instrument or your water. To make sure routine cleaning cycles are never missed, the probe offers operators customizable diagnostic alert indicators, ensuring the probe can operate at its maximum performance level.
Customizable service indicators trigger a service message so that a cleaning cycle is never missed.

No Drift

Cutting-edge 3D calibration procedure is conducted prior to shipping, the DO probe will not drift and is more accurate than ever before.

No Complications

Our newest DO probe has a robust design with a smaller footprint allows for easier handling with enhanced durability.

What's included?

Includes: LDO probe, calibation bags, and manual

Specifications

Accuracy: ± 0.05 ppm Below 5 ppm
Accuracy 2: ± 0.1 ppm Above 5 ppm
Accuracy 3: Temperature: ± 0.2 °C
Body material: Noryl
Cable Length: 10 m (33 ft)
Calibration Method: All Probes are factory calibrated and ready to use
Air Calibration: one point, 100% water saturated air
Sample Calibration: comparison to standard instrument, or comparison to Winkler Titration method
Controller Compatibility: SC4500, SC1000
Diameter: 48.25 mm
Dimensions (D x L): 48.25 mm x 254 mm
Flow Rate: None required
Hazardous Location Ratings: ETL listed (cETLus marked) to Canadian and US General Safety and Hazardous (Class l, Div. 2) Locations
Interferences: No Interferences from the following: H2S, pH, K+, Na+, Mg2+, Ca2+, NH4+, Al3+, Pb2+, Cd2+, Zn2+, Cr (total), Fe2+, Fe3+, Mn2+, Cu2+, Ni2+, Co2+, CN-, NO3-, SO42-, S2-, PO43-, Cl-, anion active surfactants, crude oils, Cl2 < 4 ppm
Length: 254 mm
Measurement Range 2: 0 - 20.00 mg/L
Measurement Range 3: 0 - 200 %
Operating temperature range: 0 - 50 °C
Options: Sea Water Application
Pressure Range: 3.5 bar
Range: 0 - 20.00 ppm
Repeatability: ± 0.1 ppm (mg/L)
Resolution: 0.01 ppm (mg/L)
0.1% saturation
Response time: T90 < 40 s
T95 < 60 s
Sensor Cable: 10 m
Sensor Immersion Depth: Down to 34 m (112 ft.), 345 kPa (50 psi), maximum; accuracy may not be maintained at this depth
Storage conditions: -20 °C to 70 °C
Transmission Distance: 1000 m (3280 ft.) maximum when used with a termination box
  100 m (328 ft.) maximum
Warranty: 36 months
Weight: 1 kg (2.2 lbs), probe only
What's included?: Includes: LDO probe, calibation bags, and manual