Hach LDO sc Model 2, DO Probe with Luminescent Dissolved Oxygen Technology

Hach LDO sc Model 2, DO Probe with Luminescent Dissolved Oxygen Technology
Product #: 9020000
Unit Price Contact Hach

No Calibration Required

The Hach LDO sc probe uses luminescent dissolved oxygen technology. Traditional membrane style DO probes require sensor calibration, which increase maintenance requirements.

No Membranes to Replace

There is virtually no maintenance with Hach's breakthrough luminescent technology. There are no membranes to replace, no electrolyte solution to replenish, and no anode or cathode to clean.

No Missed Cleaning Cycles

The Hach LDO sc probe is equipped with Prognosys, a predictive diagnostic system, that allows you to be proactive in your maintenance by alerting you to upcoming instrument issues. Know with confidence whether changes in your dissolved oxygen level measurements are due to changes in your instrument or your water. To make sure routine cleaning cycles are never missed, the probe offers operators customizable diagnostic alert indicators, ensuring the probe can operate at its maximum performance level.
Customizable service indicators trigger a service message so that a cleaning cycle is never missed.

No Drift Technology

Cutting-edge 3D calibration procedure is conducted prior to shipping, the DO probe will not drift and is more accurate than ever before, compared to membrane style probes.

No Complications

Our newest Model 2 DO probe has a robust design with a smaller footprint allows for easier handling with enhanced durability.

What's included?

Includes: sensor with cable, calibration bags, and manual

Specifications

Accuracy: ± 0.05 ppm Below 5 ppm
Accuracy 2: ± 0.1 ppm Above 5 ppm
Accuracy 3: Temperature: ± 0.2 °C
Body material: Stainless
Cable Length: 10 m (33 ft)
Calibration Method: All Probes are factory calibrated and ready to use
Air Calibration: one point, 100% water saturated air
Sample Calibration: comparison to standard instrument, or comparison to Winkler Titration method
Communication: Modbus
Controller Compatibility: SC4500, SC1000
Diameter: 48.25 mm
Dimensions (D x L): 48.25 mm x 254 mm
Flow Rate: None required
Hazardous Location Ratings: ETL listed (cETLus marked) to Canadian and US General Safety and Hazardous (Class l, Div. 2) Locations
Interferences: No Interferences from the following: H2S, pH, K+, Na+, Mg2+, Ca2+, NH4+, Al3+, Pb2+, Cd2+, Zn2+, Cr (total), Fe2+, Fe3+, Mn2+, Cu2+, Ni2+, Co2+, CN-, NO3-, SO42-, S2-, PO43-, Cl-, anion active surfactants, crude oils, Cl2 < 4 ppm
Length: 254 mm
Measurement Range 2: 0 - 20.00 mg/L
Measurement Range 3: 0 - 200% saturation
Operating temperature range: 0 - 50 °C
Options: None
Pressure Range: Max 3.5 bar
Range: 0 - 20.00 ppm
Repeatability: ± 0.1 ppm (mg/L)
Resolution: 0.01 ppm (mg/L)
0.1% saturation
Response time: T90 < 40 s
T95 < 60 s
Sensor Cable: 10 m (31 ft.) terminated with quick-disconnect plug
Sensor Immersion Depth: Down to 34 m (112 ft.), 345 kPa (50 psi), maximum; accuracy may not be maintained at this depth
Sensor Thread: Outer thread
Storage conditions: -20 °C to 70 °C
Transmission Distance: 100 m (328 ft.) maximum
  400 m (1312 ft.) maximum when used with a termination box
Warranty: 36 months
Weight: 1 kg (2.2 lbs), probe only
Wetted Materials: Sensor Cap: Acrylic; Probe Body: CPVC, Polyurethane, FKM/FPM, Noryl, 316 Stainless Steel
What's included?: Includes: sensor with cable, calibration bags, and manual