Accessories Included:
No
Automatic Buffer Recognition:
Yes
Backlight:
Yes
Barometric Pressure Measurement:
Automatic compensation of DO when using an LDO or LBOD probe
Cable Length:
1 m
Calibration Intervals/Alerts/Reminder:
Off, selectable from 2 hours to 7 days
Certifications:
CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
Data Export:
USB connection to PC or USB storage device (limited to the storage device capacity).
Data Memory:
5000 data points
Data Storage:
Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
Dimensions (H x W x D):
63 mm x 97 mm x 220 mm
Display:
Up to 3 parameters at a time, dependent on HQ model
Display Type:
536x336 Mono-TFT
DO Measurement Range:
0.1 - 20.0 mg/L (ppm), 1 - 200% saturation
DO Resolution:
0.1
Enclosure Rating:
IP67 (with battery compartment installed)
GLP Features:
Date; Time; Sample ID; Operator ID, Calibration
Inputs:
1
Instrument:
Portable
ISE Direct Measurement Range:
No
ISE Electrode Calibration:
No
Kit?:
Yes
Languages:
English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
Lock Function:
Continuous / Auto-stabilisation ("press to read") / At Interval
Measurement method:
Probe specific programmed method settings
Model:
HQ1130 DO/1 Channel
mV Measurement at Stable Reading:
No
mV Measurement Range:
No
Operating Error Messages:
Clear text error messages displayed
Operating Humidity:
90% (non-condensing)
Operating Interface:
Soft Touch Keypad
Operating Temperature:
0 - 60 °C
Parameter:
Dissolved Oxygen
Power supply:
Rechargeable lithium-ion battery 18650 (internal)
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
Probes included:
LDO10101
Probe Type:
Intellical Standard Laboratory or Rugged Field
Protection Class:
IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external
Sensor A:
LDO10101
Sensor B:
None
Sensor C:
None
Storage conditions:
-20 - 60 °C, max. 90% relative humidity (non-condensing)
Temperature Compensation:
Automatic Temperature compensation for pH
Temperature Measurement:
°C or °F
Temperature Resolution:
0.1 °C
Type of measurement:
Field Measurements
Warranty:
12 months
Weight:
519 g (Meter only)
What's included?:
LEV015.53.1130A HQ1130 Portable DO Meter, 1 channel
LDO10101 Intellical dissolved oxygen (DO) sensor, 1 m cable
LEZ015.99.A001A HQ standard electrode field case
LEZ015.99A003A HQ hand strap & kickstand
LEZ015.99.A004A HQ protective glove
2097000 Disposable wipes, 11x22 cm, pk/280
User manuals