Alarm:
                                            
                                            
                                        
									    Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Base Configuration:
                                            
                                            
                                        
									    Portable Compact
                                    
                                
    						
								
                                    
                                        
                                            
                                                Base Type:
                                            
                                            
                                        
									    Compact
                                    
                                
    						
								
                                    
                                        
                                            
                                                Body material:
                                            
                                            
                                        
									    Impact resistant ABS plastic, 3-section construction Double-walled base with 2.54 cm insulation, direct ice contact with bottles (Sampler)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Bottle Set:
                                            
                                            
                                        
									    Discrete (24) 575 mL polyethylene bottle kit for standard base
                                    
                                
    						
								
                                    
                                        
                                            
                                                Communication Capabilities:
                                            
                                            
                                        
									    USB and optional RS485 (Modbus)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Data logging:
                                            
                                            
                                        
									    SAMPLE HISTORY - Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).
MEASUREMENTS - Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.
EVENTS - Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Diagnostics:
                                            
                                            
                                        
									    View event and alarm logs as well as maintenance diagnostics
                                    
                                
    						
								
                                    
                                        
                                            
                                                Display:
                                            
                                            
                                        
									    1/4 VGA, Colour; self-prompting/menu-driven program
                                    
                                
    						
								
                                    
                                        
                                            
                                                Factory Installed Options:
                                            
                                            
                                        
									    
Please contact your Hach sales representative for details.
                                    
                                
                                    
                                        
                                            
                                            
                                                 
                                            
                                        
									    NON-CONTACT LIQUID DETECT
Sample volume accuracy for applications that require complete tubing replacement
                                    
                                
                                    
                                        
                                            
                                            
                                                 
                                            
                                        
									    RAIN/RS485 PORT
Accepts Hach Rain Gauge (not included) or can be used as RS485 communications
                                    
                                
                                    
                                        
                                            
                                            
                                                 
                                            
                                        
									    TWO SENSOR PORTS
Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors
                                    
                                
    						
								
                                    
                                        
                                            
                                                Housing Material:
                                            
                                            
                                        
									    PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Inputs:
                                            
                                            
                                        
									    One 0/4-20 mA input for flow pacing
                                    
                                
    						
								
                                    
                                        
                                            
                                                Intake:
                                            
                                            
                                        
									    Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Purge: Air purged automatically before and after each sample;
duration automatically compensates for varying intake line lengths
Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses
Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
                                    
                                
    						
								
                                    
                                        
                                            
                                                Internal Clock:
                                            
                                            
                                        
									    ±1 second per day at 25 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Languages:
                                            
                                            
                                        
									    en, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko
                                    
                                
    						
								
                                    
                                        
                                            
                                                Lock Function:
                                            
                                            
                                        
									    Access code protection prevents tampering
                                    
                                
    						
								
                                    
                                        
                                            
                                                Manual Sampling:
                                            
                                            
                                        
									    Initiates a sample collection independent of program in progress
                                    
                                
    						
								
                                    
                                        
                                            
                                                Memory:
                                            
                                            
                                        
									    Sample history: 4000 records;
Data log: 325,000 records;
Event log: 2000 records
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating Mode:
                                            
                                            
                                        
									    Continuous or non-continuous
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating temperature range:
                                            
                                            
                                        
									    0 - 50 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Hz):
                                            
                                            
                                        
									    50 - 60 Hz
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    230 V
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power supply:
                                            
                                            
                                        
									    230 V, 3 pin to sampler. EU plug.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Probes included:
                                            
                                            
                                        
									    No
                                    
                                
    						
								
                                    
                                        
                                            
                                                Programs:
                                            
                                            
                                        
									    Dual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
                                    
                                
    						
								
                                    
                                        
                                            
                                                Pump flow rate:
                                            
                                            
                                        
									    4.8 L/min at 1 m vertical lift with 3/8" intake tube typical
                                    
                                
    						
								
                                    
                                        
                                            
                                                Rain Gauge Enabled:
                                            
                                            
                                        
									    No
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Container:
                                            
                                            
                                        
									    24 x 575 mL PE
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Interval:
                                            
                                            
                                        
									    Selectable in single increments from 1 to 9999 flow pulses or 1 to 9999 mins in one minute increments
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Pump:
                                            
                                            
                                        
									    High-speed peristaltic, dual roller, with 0.95 ID x 1.6 OD cm (3/8" ID x 5/8" OD) pump tube
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Temperature:
                                            
                                            
                                        
									    0 - 60 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Transport Velocity:
                                            
                                            
                                        
									    0.9 m/s with 4.6 m vertical lift, 4.8 m of 3/8" Vinyl intake tubing, 21 °C and 1524 m elevation
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Trigger:
                                            
                                            
                                        
									    When equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Volume:
                                            
                                            
                                        
									    Programmable in 10 mL increments from 10 - 10,000 mL
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Volume Accuracy:
                                            
                                            
                                        
									    Typical: ±5% of 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8" Vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m elevation
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Volume Repeatability:
                                            
                                            
                                        
									    Typical: ±5% of 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8" Vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m elevation
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sampling Mode:
                                            
                                            
                                        
									    Pacing: Time weighted, Flow weighted, Time table, Flow table, Event
Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sensor Ports:
                                            
                                            
                                        
									    None
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sensors:
                                            
                                            
                                        
									    None
                                    
                                
    						
								
                                    
                                        
                                            
                                                Status Messages:
                                            
                                            
                                        
									    Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
                                    
                                
    						
								
                                    
                                        
                                            
                                                Storage conditions:
                                            
                                            
                                        
									    -30 - 60 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Suction Hose Outer Diameter:
                                            
                                            
                                        
									    1/4" and 3/8" ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Tubing:
                                            
                                            
                                        
									    Vinyl - 25', 3/8" ID x 5/8" OD tubing and PTFE/stainless steel strainer
                                    
                                
    						
								
                                    
                                        
                                            
                                                User Interface:
                                            
                                            
                                        
									    Membrane switch keypad with 2 multiple function soft keys
                                    
                                
    						
								
                                    
                                        
                                            
                                                Vertical Lift:
                                            
                                            
                                        
									    8.5 m using 8.8 m maximum of 3/8" Vinyl intake tube at sea level at 20 to 25 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    12.7 kg
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    1 ea. AS950 controller on compact portable base
1 ea. power supply, with 3-pin connector, 230 V (8754500EU)
1 ea. Bottle kit (PC240575) includes 24x 575mL  polyethylene bottles w/caps (1369) retainer (1422) and distributor arm (8580)
1 ea. 25' vinyl intake tubing (920)
1 ea. strainer (926)