Promotions INQUIRY: +91 9916040249

EZ1017sc Calcium Hardness Colorimetric Analyser, 1 stream, 4x mA Output

EZ1017sc Calcium Hardness Colorimetric Analyser, 1 stream, 4x mA Output
Product #: EZ1017.9700140T
Unit Price Contact Hach

Performance in Challenging Environments

Designed to excel in tough conditions, the system features preconditioning solutions, including self-cleaning filtration panels that seamlessly integrate with EZ sc analyzers. These prefiltration panels ensure reliable, long-term performance while minimizing maintenance needs, making them ideal for demanding applications.

Cost-Effective and Scalable Monitoring

With support for up to 8 streams, the EZ1017sc reduces per-sampling-point costs while delivering comprehensive insights. Its flexible, scalable design adapts to your evolving monitoring needs, from basic to complex analyses.

Enhanced Operational Efficiency with Advanced Connectivity

Real-time data and advanced connectivity improve reaction times, enabling faster, more informed decisions. Integrate the EZ1017sc with your systems using configurable analogue or digital outputs for optimized performance.

What's included?

EZ1017sc Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)

Specifications

Alarm: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Ambient Temperature: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Analog Outputs: Active 4 - 20 mA max. 500 Ohm load, standard 4, max. 8 (option)
Automatic cleaning: Yes
Calibration: Automatic, 2-point; frequency freely programmable
Certifications: CE compliant / ETL certified
Cooling water: Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Cycle Time: 10 min (dilution + 5 min.)
Demineralised water: When needed for rinsing / dilution
Digital outputs: None
Optional: Modbus (TCP/IP, RTU), Profinet, Profibus DP, Ethernet IP
Dimensions (H x W x D): 688 mm x 460 mm x 340 mm
Drain: Atmospheric pressure, vented, min. Ø 32 mm
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferences: Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Lower Limit of Detection (LOD): ≤ 2.5 µg/L CaCO3
Material: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Measurement method: Colorimetric measurement at 610 nm using hydroxynaphthol blue/EDTA
Number of sample streams: Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Parameter: Calcium Hardness
Power: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Precision: Better than 2% full scale range for standard test solutions
Protection Class: IP44
Range: 0.005 - 0.25 mg/L CaCO3
0.005 - 0.5 mg/L CaCO3
0.025 - 1 mg/L CaCO3
0.125 - 5 mg/L CaCO3 (with internal dilution)
0.25 - 10 mg/L CaCO3 (with internal dilution)
0.625 - 25 mg/L CaCO3 (with internal dilution)
1.25 - 50 mg/L CaCO3 (with internal dilution)
1.875 - 75 mg/L CaCO3 (with internal dilution)
2.5 - 100 mg/L CaCO3 (with internal dilution)
Reagent Requirements: Keep between 5 - 20 °C in use
Sample Flow Rate: 100 - 300 mL/min
Sample Pressure: By external overflow vessel
Sample Quality: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Sample Temperature: 10 - 30 °C
Validation: Automatic; frequency freely programmable
Warranty: 12 months
Weight: 40 kg
What's included?: EZ1017sc Calcium Hardness Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 3 x empty 2.5L Reagent Containers with Fittings (for Colour, Acid, and EDTA Solution) and 1 x empty 5L Reagent Container with Fittings (for Buffer)